Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Ottima qualità grafica e completo nelle notizie. Costo abbastanza contenuto.
;
Great and quick support. The maual was exactly what I was looking for and my problem
solved. Many thanks.
;
Very good service Within one day i received a pdf of the users manual and electric circuits so I was able to measure the different voltages in the printed circuit and find out the fault Payment was also reliable and easy.Without the manual i could not have repaired.So thanks to "Search for a manual"
;
you are doing great job guys.....my father ask me to find out the schematics of Sony KV25R1D to sort out the problem ..(he was electrical technician, and excperianced with TV and simillar stuff). finally he found the cause and change all necessary parts....now he has got working old dog..and is very happy!!... thank you all.. NB..he also saved the repair cost.
;
Perfect. Received my manual within 24 hours. Clear scan of the manual I needed. No problem.
MEASUREMENT WITH THE OUTER CASE REMOVED
� When you replace the magnetron, measure microwave energy leakage before the out case is installed and after all necessary components are replaced or adjusted. Special care should be taken in measuring the following parts. (Shaded area of below Fig.) � Around the magnetron � The waveguide
NOTES WHEN MEASURING
� Do not exceed meter full scale deflection. � The test probe must be removed no faster than, 1 inch/sec (2.5 cm/sec) along the shaded area, otherwise a false reading may result. � The test probe must be held with the grip portion of the handle. A false reading may result if the operator�s hand is between the handle and the probe. � When testing near a corner of the door, keep the probe perpendicular to the surface making sure the probe horizontally along the oven surface, this may possibly cause probe damage.
WARNING: AVOID CONTACTING ANY HIGH VOLTAGE PARTS
RECORD KEEPING AND NOTIFICATION AFTER MEASUREMENT
� After adjustment and repair of any microwave energy interruption or microwave energy blocking device, record the measured values for future reference. Also enter the information on the service invoice. � Should the microwave energy leakage not be more than 4 mW/cm2 after determining that all parts are in good condition, functioning properly and genuine replacement parts which are listed in this manual have been used. � At least once a year, have the electromagnetic energy leakage monitor checked for calibration by its manufacture.
MEASUREMENT WITH A FULLY ASSEMBLED OVEN
� After all components, including the outer case, are fully assembled, measure for microwave energy leakage around the door viewing window, the exhaust opening and air inlet openings. � Microwave energy leakage must not exceed the values prescribed below. NOTES: Leakage with the outer case removed - less than 5 mW/cm2. Leakage for a fully assembled oven (�Before the latch switch (primary) is interrupted�) with the door in a slightly opened position - less than 4 mW/cm2.
5-2
|
|
|
> |
|